FULL PRESCRIBING INFORMATION

Uses





TERUFLEX BLOOD BAG SYSTEM with Diversion Blood Sampling Arm

CPDA-1 SOLUTION
For the collection of 450 mL and 500 mL of Whole Blood

FULL PRESCRIBING INFORMATION



1.    INDICATIONS AND USAGE







2.   DOSAGE AND ADMINISTRATION

2.1.   To open blister package, peel cover film back 4/5 of its length.

2.2.   Prepare the blood bag following your institution's standard operating procedures.

    2.2.1.    Materials Needed:   VENOJECT II Tube Holder (code P-1316R) or equivalent

                                             VENOJECT II Multi-sample Luer Adapter (code MN*2000T) or equivalent

                                              Evacuated blood collection tubes (glass or plastic)

2.3.   Make a loose knot in the donor tubing below the "Y" and CLIKTIP (inline closure device) unless alternate methods are used to seal the tubing at the end of collection.

2.4.   Temporarily clamp donor tubing between the phlebotomy needle and the "Y".

2.5.   Close the White Clamp below the diversion pouch.

2.6   Assemble the luer adapter and the tube holder.

    2.6.1.    Connect the VENOJECT II Multi-Sample Luer Adapter to the VENOJECT II Tube Holder (or equivalent) (Fig. 1).

    2.6.2.    Twist and snap to remove the blue port cap at the end of the Diversion Blood Sampling Arm (Fig. 2a).

    2.6.3.    Insert the Holder/Luer assembly in the female luer port (Fig. 2b).

    2.6.4.   NOTE: Alternatively, steps 2.6.1., 2.6.2. and 2.6.3. (above) may be performed at any time during bag preparation or after the blood is collected into the diversion pouch.

Fig.1

TERUFLEX Blood Bag System Anticoagulant Citrate Phosphate Dextrose Adenine (CPDA-1)

Fig. 2a/Fig. 2b

TERUFLEX Blood Bag System Anticoagulant Citrate Phosphate Dextrose Adenine (CPDA-1)


2.7    Suspend the collection bag as far as possible below the donor's arm.

2.8.   Apply blood pressure cuff or tourniquet to donor's arm. Disinfect site of phlebotomy. If blood pressure cuff is used, inflate cuff to approximately 60 mmHg.

2.9.   Remove the needle cover and perform phlebotomy. Remove the temporary clamp on the donor tubing to permit blood flow into the Diversion Blood Sampling Arm pouch.

    2.9.1.    CAUTION:   Do not touch the needle after removing the needle cover.

CAUTION

2.10.   Secure the needle safety device in place following the device instructions provided on the reverse side.

2.11.   Secure donor tubing to donor's arm.

2.12.   Position the diversion pouch with the notches up and the Tube Holder/Luer Adapter assembly (or port cap) down. When the level of blood in the pouch is approximately in line with the notches, the diversion pouch is full (Fig. 3a).

    2.12.1.   NOTE: The approximate fill volume of the pouch at the notches is 35 mL.

2.13.   Permanently seal the tubing between the "Y" and the diversion pouch to maintain a closed system using an aluminum clip or a tube sealer approved for use with tubing connected to a donor (Fig. 3b).

    2.13.1   Do not use a dielectric tube sealer to seal tubing while the needle is connected to the donor's body unless it is approved for such a purpose.

2.14.   To initiate blood flow into the collection bag, break the CLIKTIP between the "Y" and the collection bag.

2.15.   To avoid clot formation, collect samples as soon as possible from the diversion pouch as follows (Fig. 3b).

    2.15.1    CAUTION: Do not collect donor test samples until the tubing between the "Y" and the diversion pouch is permanently sealed.

    2.15.2.   Open the White Clamp on the tubing below the pouch to open the pathway for sampling.

    2.15.3.   Position the diversion pouch with the notches up and the Tube Holder/Luer Adapter assembly downward. Assure that any air in the pouch is at the top and will not enter the blood collection tubes.

    2.15.4.   Insert blood collection tube firmly into the tube holder; when full, remove sample tube from holder. Repeat to collect additional samples.

    2.15.5.   NOTE: The pouch may be removed after the donor test samples are collected. A second seal must be made between the diversion pouch and the permanent seal prior to removing the pouch.


TERUFLEX Blood Bag System Anticoagulant Citrate Phosphate Dextrose Adenine (CPDA-1)

2.16    Mix blood with anticoagulant in the collection bag and continue to mix at several intervals during collection and immediately after collection. If using an automated mixer, follow manufacturer's instructions.

2.17.   Collect labeled volume of blood 450 mL +/- 10% or 500 mL +/- 10%.

2.18.   When the desired amount of blood has been collected, seal the tubing or tighten the loose knot (white knot) prepared in Step 2.3. Make a second seal between the first seal or knot and the "Y". Various methods may be used to seal tubing.



CAUTION



ooo

o
o




o
o





3.   DOSAGE FORMS AND STRENGTHS

3.1.   63 mL Citrate Phosphate Dextrose Adenine (CPDA-1) anticoagulant for collection of 450 mL Whole Blood. Each 63 mL contains 188 mg Citric Acid (anhydrous) USP, 1.66 g Sodium Citrate (dihydrate) USP, 140 mg Monobasic Sodium Phosphate (monohydrate) USP, 2.01 g Dextrose (monohydrate) USP and 17.3 mg Adenine USP.


5.   WARNINGS AND PRECAUTIONS

5.1.   Rx ONLY

5.2.   Do not use unless solutions are clear and free from particulates.

5.3.   Always inspect the blood bag set for leaks before use.

5.4.   Avoid excessive heat and direct sunlight. Protect from freezing.

5.5.   Recommended storage conditions: Room Temperature (15-30oC/59-86oF).

5.6.   It is normal to have condensation in the blister packaging. If the amount of moisture is greater than expected, check for leaks from the fluid-filled components of the blood bag set.

5.7.   Use aseptic techniques.

5.8.   Do not use a dielectric tube sealer to seal the tubing while the needle is connected to the donor's body unless it is approved for such a purpose.

5.9.   Do not touch needle after removing the needle cover.

5.10.   Assure that the White Clamp below the pouch is closed prior to initiating phlebotomy.

5.11    Do not collect donor test samples until the tubing between the "Y" and the diversion pouch is permanently sealed.

5.12    Discard the Diversion Blood Sampling Arm and phlebotomy needle/donor tubing according to institutional procedures.

5.13.   The AGELESS (oxygen absorber packet, Mitsubishi Gas Chemical) contained in this package absorbs oxygen and generates heat on removal. Do not open and handle it with care.

5.14.   Dispose of the AGELESS packet with the blister tray.

5.15.   Do not dispose the AGELESS packet with wastes containing volatile or flammable materials.

5.16.   Due to possible exposure to infectious agents in the handling of blood, take adequate precautions at all times to prevent exposure to and transmission of such agents. Follow your institution's standard operating procedures.



11.   DESCRIPTION/PRODUCT SPECIFICATIONS

11.1.   This blood bag system includes a 16 gauge x 1 1/2 inch (1.60 x 38 mm) needle with needle cover and either 450 mL or 500 mL (nominal capacity 600 mL) primary collection bag containing 63 mL or 70 mL, respectively, Citrate Phosphate Dextrose Adenine (CPDA-1) anticoagulant. The Triple blood bag set has one integrally attached empty satellite bag (nominal capacity 400 mL) and one empty XT-612 5 day Platelet bag (nominal capacity 500 mL). The Quadruple blood bag set has two integrally attached empty satellite bags (nominal capacity 400 mL) and one empty XT-612 5 day Platelet bag (nominal capacity 500 mL).

11.2.   Blood bag codes ending in A2 are supplied with Integral Diversion Blood Sampling Arm intended to divert and obtain donor samples for laboratory testing prior to collection of the Whole Blood unit.

11.3.   Blood bag codes ending in A2 also include a DonorCare Needle Guard pre-attached to the donor tubing. DonorCare Needle Guard device instructions are provided on the reverse side.

11.4.   The blood bag collection set is made of PVC (polyvinyl chloride with DEHP plasticizer).

11.5.   The blood bag has no components made of natural rubber latex.

11.6.   Tubing internal diameter (ID) nominal 3.0 mm.

11.7.   Tubing outer diameter (OD) nominal 4.4 mm.

11.8.   Donor tubing line maximum 16 segments available.


16.   HOW SUPPLIED/STORAGE AND HANDLING

16.1.   Single use only.

16.2.   Sterile and non-pyrogenic fluid path. Sterilized by steam. Opacity of the blood bag system may be observed. This is due to moisture absorption during the sterilization process. This is normal and does not affect the solution quality or safety. The opacity will diminish gradually.

16.3.   A Material Safety Data Sheet (MSDS) is not required for this product.

16.4.   Recommended storage conditions: Room Temperature (15-30oC/59-86oF).

16.5.   Avoid excessive heat and direct sunlight. Protect from freezing.

16.6.   To open blister package, peel cover film back 4/5 of its length. (See Figure Sealing with tape)

Figure Sealing with tape

TERUFLEX Blood Bag System Anticoagulant Citrate Phosphate Dextrose Adenine (CPDA-1)

16.7.   After opening the blister package, unused blood bags may be stored at room temperature for 96 hours or they may be stored for 30 days by returning cover film to original position and sealing with tape to prevent evaporation of solutions.

16.8.   Blood bags in the unopened blister package may be used through the last day of the month and year as indicated on the original manufacturer's packaging.

16.9.   The AGELESS packet contained in this package absorbs oxygen and generates heat on removal. Do not open and handle it with care.

16.10.   Dispose of the AGELESS packet with the blister tray.

16.11   Do not dispose the AGELESS packet with wastes containing volatile or flammable materials.

16.12.   For the Triple blood bag set, Codes BB*TCD456A2 and BB*TCD506A2 are supplied 30/case.

16.13.   For the Quadruple blood bag set, Codes BB*QCD456A2 and BB*QCD506A2 are supplied 24/case.


MANUFACTURED BY:

TERUMO CORPORATION
44-1, 2-CHOME, HATAGAYA, SHIBUYA-KU,

TOKYO 151-0072, JAPAN

MADE IN JAPAN

(R): Registered Trademark

DonorCare is a registered trademark of ITL Corporation Melbourne, Australia.

AGELESS is a registered trademark of MITSUBISHI GAS CHEMICAL CO., INC.

(c) TERUMO CORPORATION November, 2011 11K09



Tray/Case Label
TERUFLEX BLOOD BAG SYSTEM with Diversion Blood Sampling Arm

ANTICOAGULANT CITRATE PHOSPHATE
DEXTROSE ADENINE SOLUTION (CPDA-1) USP
FOR COLLECTION OF 500mL OF BLOOD


Each unit consists of a primary bag containing 70 mL of solution with
209 mg Citric Acid (anhydrous) USP, 1.84 9 Sodium Citrate (dihydrate)
USP, 155 mg Monobasic Sodium Phosphate (monohydrate) USP, 2.23 9
Dextrose (monohydrate) USP, 19.3 mg Adenine USP.

STERILE, NON-PYROGENIC FLUID PATH.
DO NOT USE UNLESS ANTICOAGULANT IS CLEAR.

CODE

LOT NO.

EXPIRY

UNITS


DONOR NEEDLE 16G X 1 1/2" (1.60 X 38mm)
RxONLY


RECOMMENDED STORAGE: Room Temperature (15-30°C/59-86°F).
Avoid excessive heat. Protect from freezing.

After opening, unused bags may be stored at room temperature for 96 hours or they may be stored for 30 days in the blister package after returning the cover film to original
position and sealing with tape to prevent possible loss of moisture.
See Instructions For Blood Collection.

Manufactured by: TERUMO CORPORATION Tokyo, Japan
(R) : Registered Trademark
Issued 2009-09

B-2-H6-A2

Image of Representative Tray/Case Label CPDA-1 500mL with DBSA

TERUFLEX Blood Bag System Anticoagulant Citrate Phosphate Dextrose Adenine (CPDA-1)


TERUFLEX Blood Bag System Anticoagulant Citrate Phosphate Dextrose Adenine (CPDA-1)

Anticoagulant Citrate Phosphate Dextrose Adenine (CPDA-1) SOLUTION

Product Information

Product Type Human prescription drug label Item Code (Source) NDC:53877-001
Route of Administration INTRAVENOUS DEA Schedule

Active Ingredient/Active Moiety

Ingredient Name Basis of Strength Strength
ANHYDROUS CITRIC ACID ANHYDROUS CITRIC ACID 2.99 g
TRISODIUM CITRATE DIHYDRATE 26.3 g
Sodium Phosphate, Monobasic, Monohydrate 2.22 g
Dextrose monohydrate ANHYDROUS DEXTROSE 31.9 g
Adenine ADENINE 0.275 g

Inactive Ingredients

Ingredient Name Strength
water

Packaging

# Item Code Package Description Marketing Start Date Marketing End Date
1 63 in 1 BAG
2 63 in 1 BAG
3 70 in 1 BAG
4 70 in 1 BAG
5 NDC:53877-001-14 24 in 1 CASE

Marketing Information

Marketing Category Application Number or Monograph Citation Marketing Start Date Marketing End Date
BN BN820528 2012-05-22


PLEASE, BE CAREFUL!
Be sure to consult your doctor before taking any medication!
Copyright © 2014. drugs-library.com. All rights reserved. Information on drugs-library.com is provided for educational purposes only and is not to be used for medical advice, diagnosis or treatment.
Support info@drugs-library.com.